Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
J Ultrasound Med ; 43(5): 913-921, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38284137

RESUMO

OBJECTIVES: The changes of the extracellular matrix of the connective tissue have significantly contributed to the incidence of pelvic organ prolapse (POP). It seems reasonable that sonoelastography could be a useful tool to evaluate the elasticity of pelvic floor tissue in patients with POP and compare it to those without POP. The main aim of this pilot study was to determine if there are differences in the elasticity of the levator ani muscle (LAM) and vaginal tissue between patients with and without POP. METHODS: Prospective observation study, including 60 patients (30 with POP and 30 without POP). Sonoelastography was performed to evaluate the elasticity (in kilopascals, kPa) of the following regions of interest: vagina at the level of middle third of the urethra; vagina at the level of the bladder trigone; vagina in the anterior and posterior fornix; vagina at the level of middle third of the anorectal canal; posterior third of the LAM. RESULTS: A total of 60 patients completed the study (30 with POP, 30 without POP). In the POP group, 18/30 (60%) had an anterior vaginal wall prolapse, 3/30 (10%) a uterine prolapse, 15/30 (50%) a rectocele, and 6/30 (20%) a enterocele. Patients with POP had higher elasticity in all anatomical study areas, with statistically significant differences in the anterior fornix (13.6 vs 11.2 kPa; P: .012). A multiple regression (controlling age, menopausal stage, and parity) allowed to detect statistically significant differences in the elasticity of the middle third of the urethra (P: .03) and the middle third of the anorectal canal (P: .019). CONCLUSION: It is possible to evaluate the elasticity of the LAM and vaginal tissue using sonoelastography, detecting a higher elasticity in patients with POP than in those without POP.


Assuntos
Técnicas de Imagem por Elasticidade , Prolapso de Órgão Pélvico , Prolapso Uterino , Gravidez , Feminino , Humanos , Técnicas de Imagem por Elasticidade/efeitos adversos , Estudos Prospectivos , Projetos Piloto , Vagina/diagnóstico por imagem , Prolapso de Órgão Pélvico/diagnóstico por imagem , Diafragma da Pelve/diagnóstico por imagem , Elasticidade
2.
J Ultrasound Med ; 43(2): 265-272, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37853913

RESUMO

OBJECTIVE: To determine if the addition of the assessment of levator ani muscle (LAM) avulsion to the measurement of the difference in the pubis-uterine fundus distance between rest and with the Valsalva maneuver could increase the diagnostic capacity of ultrasound for uterine prolapse (UP). METHODS: This multicenter, observational and prospective study included 145 patients. Ultrasound assessment was performed, establishing the diagnosis of UP as a difference between the pubic-uterine fundus distance at rest and during the Valsalva maneuver ≥15 mm (standard technique), while LAM avulsion was defined as an abnormal LAM insertion in three central slices using multislice ultrasound. A binary multivariate logistic regression model was made using nonautomated methods to predict surgical UP (general population, premenopausal, and postmenopausal patients), including the difference between the pubis-uterine fundus distance at rest and with the Valsalva maneuver as well as LAM avulsion. RESULTS: A total of 143 patients completed the study. The addition of LAM avulsion criteria to the standard dynamic distance-based protocol for the diagnosis of UP resulted in a higher sensitivity for the general population (79.7 vs 68.1%) as well as for premenopausal (89.3 vs 79.9%) and postmenopausal patients (76 vs 66.1%). In contrast, the standard technique showed a higher specificity than the model based on the standard technique associated with LAM avulsion for the general population (89.2 vs 74.3%) and premenopausal women (91.7 vs 63.2%). For postmenopausal patients, the model based on the standard technique associated with LAM avulsion had a higher sensitivity (76 vs 66.1%) and specificity (91.7 vs 86.8%) than the ultrasound diagnosis of UP. CONCLUSION: The implementation of the assessment of LAM avulsion in the ultrasound diagnosis of UP is useful in postmenopausal patients, increasing sensitivity and specificity relative to the ultrasound assessment based only on the difference between the pubis-uterine fundus distance at rest and with the Valsalva maneuver.


Assuntos
Prolapso de Órgão Pélvico , Prolapso Uterino , Humanos , Feminino , Estudos Prospectivos , Ultrassonografia , Diafragma da Pelve/diagnóstico por imagem
3.
Diagnostics (Basel) ; 13(17)2023 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-37685323

RESUMO

BACKGROUND: Ultrasound features help to differentiate benign from malignant masses, and some of them are included in the ultrasound (US) scores. The main aim of this work is to describe the ultrasound features of certain adnexal masses of difficult classification and to analyse them according to the most frequently used US scores. METHODS: Retrospective studies of adnexal lesions are difficult to classify by US scores in women undergoing surgery. Ultrasound characteristics were analysed, and masses were classified according to the Subjective Assessment of the ultrasonographer (SA) and other US scores (IOTA Simple Rules Risk Assessment-SRRA, ADNEX model with and without CA125 and O-RADS). RESULTS: A total of 133 adnexal masses were studied (benign: 66.2%, n:88; malignant: 33.8%, n:45) in a sample of women with mean age 56.5 ± 7.8 years. Malignant lesions were identified by SA in all cases. Borderline ovarian tumors (n:13) were not always detected by some US scores (SRRA: 76.9%, ADNEX model without and with CA125: 76.9% and 84.6%) nor were serous carcinoma (n:19) (SRRA: 89.5%), clear cell carcinoma (n:9) (SRRA: 66.7%) or endometrioid carcinoma (n:4) (ADNEX model without CA125: 75.0%). While most teratomas and serous cystadenomas have been correctly differentiated, other benign lesions were misclassified because of the presence of solid areas or papillae. Fibromas (n:13) were better identified by SA (23.1% malignancy), but worse with the other US scores (SRRA: 69.2%, ADNEX model without and with CA125: 84.6% and 69.2%, O-RADS: 53.8%). Cystoadenofibromas (n:10) were difficult to distinguish from malignant masses via all scores except SRRA (SA: 70.0%, SRRA: 20.0%, ADNEX model without and with CA125: 60.0% and 50.0%, O-RADS: 90.0%). Mucinous cystadenomas (n:12) were misdiagnosed as malignant in more than 15% of the cases in all US scores (SA: 33.3%, SRRA: 16.7%, ADNEX model without and with CA125: 16.7% and 16.7%, O-RADS:41.7%). Brenner tumors are also difficult to classify using all scores. CONCLUSION: Some malignant masses (borderline ovarian tumors, serous carcinoma, clear cell carcinoma, endometrioid carcinomas) are not always detected by US scores. Fibromas, cystoadenofibromas, some mucinous cystadenomas and Brenner tumors may present solid components/papillae that may induce confusion with malignant lesions. Most teratomas and serous cystadenomas are usually correctly classified.

4.
Diagnostics (Basel) ; 13(13)2023 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-37443546

RESUMO

BACKGROUND: Several ultrasound (US) features help ultrasound experts in the classification of benign vs. malignant adnexal masses. US scores serve in this differentiation, but they all have misdiagnoses. The main objective of this study is to evaluate what ultrasound characteristics are associated with malignancy influencing ultrasound scores. METHODS: This is a retrospective analysis of ultrasound features of adnexal lesions of women managed surgically. Ultrasound characteristics were analyzed, and masses were classified by subjective assessment of the ultrasonographer (SA) and other ultrasound scores (IOTA Simple Rules Risk Assessment SRRA, ADNEX model, and O-RADS). RESULTS: Of a total of 187 adnexal masses studied, 134 were benign (71.7%) and 53 were malignant (28.3%). SA, IOTA SRRA, ADNEX model with or without CA125 and O-RADS had high levels of sensitivity (93.9%, 81.1%, 94.3%, 88.7%, 98.1%) but lower specificity (80.2%, 82.1%, 82.8%, 77.6%, 73.1%) with similar AUC (0.87, 0.87, 0.92, 0.90, 0.86). Ultrasound features significantly related with malignancy were the presence of irregular contour, absence of acoustic shadowing, vascularized solid areas, ≥1 papillae, vascularized septum, and moderate-severe ascites. CONCLUSION: IOTA SRRA, ADNEX model, and O-RADS can help in the classification of benign and malignant masses. Certain ultrasound characteristics studied in ultrasound scores are associated with malignancy.

5.
Quant Imaging Med Surg ; 13(7): 4305-4312, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37456297

RESUMO

Background: The identification of late-onset fetal growth restriction (FGR) fetuses remains a challenge, given the difficulty to distinguish them from healthy small for gestational age (SGA) fetuses. Given the limitations of conventional Doppler for the identification of placental insufficiency, the appearance of superb microvascular imaging (SMI) Doppler seems promising. Our main objective was to evaluate the diagnostic capability of SMI Doppler for the detection of placental insufficiency findings. Methods: A prospective observational study was conducted at a tertiary care center, including 51 patients who had been diagnosed with late on-set SGA or FGR. A placental ultrasonographic evaluation was carried out using SMI Doppler. Patients were sorted into two groups attending to the histologic evaluation of the placentas after delivery: Group 1 (21 cases), Normal group; and Group 2 (30 cases), FGR group. Results: Placentas in the FGR group had lower peak systolic velocity (PV) values of the chorionic plate. The PV of the other vessels were consistently lower in the FGR group that in the normal group, although without reaching statistical significance. Conclusions: The PV of the chorionic plate measured with SMI Doppler, have the capacity to identify placental insufficiency findings. Ultrasonographic placental assessment using SMI Doppler appears to be a useful technique for the evaluation of suspected late on-set placental insufficiency.

6.
J Ultrasound Med ; 42(11): 2673-2681, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37421644

RESUMO

OBJECTIVES: To validate an ultrasound software that uses transperineal ultrasound to diagnose uterine prolapse (UP). METHODS: Multicenter, observational and prospective study with 155 patients that had indications for surgical intervention for dysfunctional pelvic floor pathology. Each patient underwent an examination with Pozzi tenaculum forceps was performed in the operating room with the patient anesthetized, followed by surgical correction of stages II-IV UP. Transperineal ultrasound was used to assess the difference in the pubis-uterine fundus measurement. With a multivariate logistic regression binary model (with the measurement ultrasound at rest, the Valsalva maneuver and age) using nonautomated methods to predict UP. With the purpose of evaluating the model, a table with coordinates of the receiver operating characteristic (ROC) curve, after which sensitivity and specificity were assessed. RESULTS: A total of 153 patients were included (73 with a diagnosis of surgical UP). It was obtained from the AUC (0.89) of the probabilities predicted by the model (95% confidence interval, 0.84-0.95; P < .0005). Based on the ROC curve for the model, obtaining a sensitivity of 91.8% and a specificity of 72.7%, values that were superior to those for the clinical exam for surgical UP (sensitivity: 80.8%; specificity: 71.3%). CONCLUSIONS: We validated software that uses transperineal ultrasound of the pelvic floor and patient age to generate a more reliable diagnosis of surgical UP than that obtained from clinical examinations.

7.
J Ultrasound Med ; 42(10): 2269-2275, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37163226

RESUMO

OBJECTIVES: It is unknown whether diagnosing uterine prolapse (UP) via ultrasound or surgical criteria is superior. Our objective is to determine whether the diagnostic capacity of ultrasound with surgical criteria differs from that of surgical criteria only. METHODS: This was a multicenter prospective observational study with 54 premenopausal patients with surgical criteria for a dysfunctional pelvic floor pathology who were consecutively recruited for 1 year. Clinical UP with surgical criteria was defined when UP stage II-IV was identified (during pelvic floor consultation), and UP diagnosed by ultrasound with surgical criteria was established when a difference ≥15 mm was found between rest and Valsalva applied to the pubis-uterine fundus. The sensitivity, specificity and positive and negative predictive values were determined to evaluate clinical and ultrasound methodologies as diagnostic tests. RESULTS: UP diagnosed by ultrasound with surgical criteria presented better sensitivity (78.57 vs 35.71%), specificity (92.11 vs 81.58%), positive predictive value (61.83 vs 23.99%), and negative predictive value (96.35 vs 11.37%) than UP diagnosed by surgical criteria only. CONCLUSION: Ultrasound with surgical criteria is superior to surgical criteria alone when diagnosing UP.


Assuntos
Prolapso de Órgão Pélvico , Prolapso Uterino , Feminino , Humanos , Prolapso de Órgão Pélvico/diagnóstico por imagem , Prolapso de Órgão Pélvico/cirurgia , Útero/diagnóstico por imagem , Valor Preditivo dos Testes , Ultrassonografia/métodos
8.
Pediatr Radiol ; 53(10): 2106-2119, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37166455

RESUMO

Congenital thoracic anomalies are uncommon malformations that require a precise diagnosis to guide parental counseling and possible prenatal treatment. Prenatal ultrasound (US) is the gold standard imaging modality to first detect and characterize these abnormalities and the best modality for follow-up. Fetal magnetic resonance imaging (MRI) is a complementary tool that provides multiplanar assessment and tissue characterization and can help estimate prognosis. Prenatal treatment is increasingly being used in fetuses with signs of distress and to potentially decrease morbidity and mortality. In this essay, the authors illustrate side-by-side US, MRI and therapeutic options for congenital thoracic anomalies in cases that presented to a tertiary pediatric hospital during the 7-year period 2014-2021. Entities included are congenital diaphragmatic hernia, congenital pulmonary airway malformation, bronchopulmonary sequestration, hybrid lesions, foregut duplications cysts and congenital lobar overinflation. Treatment options include maternal steroids, thoraco-amniotic shunt and fetal endotracheal occlusion. Recognition of typical findings in congenital thoracic anomalies is helpful to establish diagnosis, predict prognosis and plan perinatal treatment.


Assuntos
Malformação Adenomatoide Cística Congênita do Pulmão , Hérnias Diafragmáticas Congênitas , Gravidez , Feminino , Humanos , Criança , Diagnóstico Pré-Natal/métodos , Hérnias Diafragmáticas Congênitas/diagnóstico por imagem , Hérnias Diafragmáticas Congênitas/cirurgia , Imageamento por Ressonância Magnética/métodos , Ultrassonografia Pré-Natal/métodos
9.
Pediatr Radiol ; 53(9): 1829-1841, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37039913

RESUMO

Fetal magnetic resonance imaging (MRI) is increasingly being used worldwide as a complementary tool to prenatal ultrasound (US) for multiple fetal pathologies. The aim of this article is to describe and illustrate how MRI can help US to evaluate fetal abdominal anomalies, based on cases performed in a tertiary public university hospital. Prenatal US, fetal MRI and postnatal imaging of these cases will be shown side-by-side to describe and illustrate the added value of fetal MRI in the different organs/systems and its impact on clinical management.


Assuntos
Diagnóstico Pré-Natal , Ultrassonografia Pré-Natal , Gravidez , Feminino , Humanos , Diagnóstico Pré-Natal/métodos , Ultrassonografia Pré-Natal/métodos , Imageamento por Ressonância Magnética/métodos , Abdome/diagnóstico por imagem , Feto , Estudos Retrospectivos
10.
Quant Imaging Med Surg ; 13(3): 1664-1671, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-36915353

RESUMO

Background: The anorectal angle (ARA) has been assessed with different imaging methods and its measurement has traditionally been based on defecography or magnetic resonance studies. Different ultrasound methodologies have also been used for ARA assessment and have been validated as alternatives for the ARA measurement, such as three-dimensional (3D) endovaginal ultrasound and 3D transperineal ultrasound. 3D transperineal ultrasound does not require the introduction of ultrasound transducers inside the anal canal. Therefore, it is reasonable to think that the use of transperineal ultrasound can provide more reproducible ARA measurements, something that has not been established by 3D endovaginal probe or defecography. Our objective is to determine the intraobserver and interobserver variability of transperineal ultrasound for the assessment of ARA. Methods: A retrospective observational study was performed with 40 patients. The study of the ARA was performed from the mid-sagittal plane (at rest, Valsalva and maximum contraction), visualizing the anorectal canal, the anorectal junction and the rectal ampulla. ARA measurements were performed initially by explorer 1 (E1), subsequently by explorer 2 (E2) and finally again by E1. Intraobserver and interobserver variability was calculated by calculating the intraclass correlation coefficient (ICC) with 95% confidence interval (CI). Results: Intraobserver variability was excellent for all measurements of the ARA at rest, Valsalva and maximal contraction, with ICC ranging from 0.968 to 0.975. Interobserver variability was also superb for all measurements of the ARA at rest, Valsalva and maximal contraction, with ICC ranging from 0.971 to 0.979. Conclusions: Intraobserver and interobserver variability were excellent for the ARA measurements by transperineal ultrasound.

11.
Tomography ; 9(1): 247-254, 2023 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-36828371

RESUMO

Although the fetal head position has traditionally been evaluated by digital examination (DE), it has a failure rate ranging between 20 and 70%; hence, intrapartum transabdominal ultrasonography (TUS) has become relevant. We aimed to evaluate the utility of the TUS to identify the fetal head positions in vacuum-assisted deliveries. We performed a prospective observational study including 101 pregnant patients in active labor who required a vacuum-assisted delivery. The fetal head position was assessed by a DE and a TUS prior to vacuum cup placement. After delivery, the optimal vacuum cup placement was evaluated as the distance between the chignon and the flexion point ≤2 cm. The general concordance rate between the DE and TUS was 72.2%, with the poorest concordance rate for occiput posterior positions at 46.1%. In five cases (4.9%), it was not possible to determine the fetal head position through the DE. The correlation was higher in low and medium planes, with 77% and 68.1% concordance rates, respectively, while it was lower in high planes (60%). In 90.1% of cases, the vacuum cup placement was optimal. Our findings show that intrapartum transabdominal ultrasonography is a useful technique to identify the fetal head position allowing optimal placement of the vacuum cup necessary for correct vacuum-assisted delivery.


Assuntos
Feto , Apresentação no Trabalho de Parto , Feminino , Gravidez , Humanos , Ultrassonografia Pré-Natal/métodos , Ultrassonografia , Vácuo-Extração/métodos
12.
Int J Gynaecol Obstet ; 160(1): 93-97, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35373338

RESUMO

OBJECTIVE: To perform a multicenter study of muscle recovery in levator ani muscle (LAM) avulsion during the first 12 months postpartum according to the type of LAM avulsion suffered. METHODS: This was a multicenter prospective observational study including 242 primiparas. Transperineal ultrasound was performed at 6 months and 12 months after delivery. Type I LAM avulsion was present when most of the lateral fibers of the pubovisceral muscle were observed at the muscle's insertion at the pubic level. Type II LAM avulsion was defined as complete detachment of the pubovisceral muscle from its insertion at the pubic level. RESULTS: Among the 56 patients who completed the study (with ultrasound at 6 and 12 months after delivery), 76 avulsions (10 cases of bilateral avulsion) were identified at 6 months after delivery, and the total number of avulsions had decreased to 58 at 12 months after delivery (P < 0.001; 95% confidence interval [CI] 13.9%-33.5%). This decrease was due to the disappearance of 69.2% of the cases of Type I LAM avulsions (P < 0.001; 95% CI: 50.2%-88.2%). However, the number of Type II LAM avulsions remained constant at 6 months and 12 months after delivery. CONCLUSION: The spontaneous resolution of LAM avulsion during the first 12 months postpartum occurs in cases of Type I LAM avulsion but is not observed in Type II LAM avulsion.


Assuntos
Diafragma da Pelve , Período Pós-Parto , Feminino , Humanos , Gravidez , Diafragma da Pelve/diagnóstico por imagem , Período Pós-Parto/fisiologia , Ultrassonografia , Parto Obstétrico
13.
Biomedicines ; 10(10)2022 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-36289845

RESUMO

Currently, cell-free DNA (cfDNA) is offered as part of a contingent screening for patients with a first-trimester combined test (FCT) risk between 1/50 and 1/250. However, most aneuploidies are within the group of patients with a risk above 1/10. An observational, retrospective, and multi-centric study was carried out, to evaluate the theorical performance of lowering the cut-off point for the high-risk group from 1/50 to 1/10. Out of the 25,920 patients included, 25,374 (97.9%) consented to the cfDNA contingent screening for aneuploidies. With the proposed strategy, knowing that the detection rate (DR) of cfDNA testing for trisomy 21 is 99.7%, the DR for trisomy 21 would have stayed in a 93.2%, just as it was with the current strategy. In this instance, 267 (1.1%) invasive tests would have been performed, while the current strategy had a total of 307 (1.2%). The false positive rate (FPR) rate would have stayed at 5.2% in both scenarios. In conclusion, the contingent screening of aneuploidies based in the result of the FCT, offering the analysis of cfDNA to patients with an intermediate risk after lowering the cut-off point from 1/50 to 1/10, is a valid alternative that might maintain the current detection rates and avoid the complications associated with invasive testing.

14.
Tomography ; 8(5): 2556-2564, 2022 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-36287812

RESUMO

It would be logical to think that single-incision mini-slings (SIMS) should behave like the rest of the tension-free vaginal tape and, therefore, to believe that they present a similar ultrasound appearance, but there are no studies on this matter. Therefore, the main aim of our research is to determine which ultrasound parameters are associated with stress urinary incontinence (SUI) in patients carrying SIMS. A prospective observational study was carried out including 94 patients who were candidates for SUI corrective surgery with SIMS between 1 January 2021 to 31 December 2021 at the Universitary Hospital of Valme (Seville, Spain). A transperineal ultrasound evaluation was performed (six months after surgery) in order to study: the bladder neck-symphyseal distance, the posterior urethro-vesical angle, the pubic symphysis-tape gap, the tape-urethral lumen distance, the sagittal tape angle, the tape position, the concordance of movement between the tape and the urethra, and the axial tape angle. A total of 92 patients completed the study (63 asymptomatic and 29 symptomatic). Statistical differences were observed in the concordance of movement between the tape and the urethra (84.1% vs. 25.0%; p: 0.001) and in the axial tape angle at rest (139.3 ± 19.0 vs. 118.3 ± 15.4; p: 0.003) and at Valsalva (145.1 ± 20.2 vs. 159.1 ± 9.0; p: 0.034). Sagittal tape angle at rest was higher in urge urinary incontinence (UUI) patients (132.5 ± 35.7 vs. 143.3 ± 29.8; p: 0.001) and mixed urinary incontinence (MUI) patients (132.5 ± 35.7 vs. 157.8 ± 23.6; p: 0.025) compared to asymptomatic patients. In conclusion, the concordance between the movement of the tape and the urethra is the most useful ultrasound parameter to define continence in patients with SIMS.


Assuntos
Slings Suburetrais , Incontinência Urinária por Estresse , Incontinência Urinária , Feminino , Humanos , Incontinência Urinária por Estresse/diagnóstico por imagem , Incontinência Urinária por Estresse/cirurgia , Incontinência Urinária/diagnóstico por imagem , Incontinência Urinária/cirurgia , Uretra/diagnóstico por imagem , Procedimentos Cirúrgicos Urológicos
15.
Tomography ; 8(4): 1716-1725, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35894009

RESUMO

We want to describe a model that allows the use of transperineal ultrasound to define the probability of experiencing uterine prolapse (UP). This was a prospective observational study involving 107 patients with UP or cervical elongation (CE) without UP. The ultrasound study was performed using transperineal ultrasound and evaluated the differences in the pubis−uterine fundus distance at rest and with the Valsalva maneuver. We generated different multivariate binary logistic regression models using nonautomated methods to predict UP, including the difference in the pubis−uterine fundus distance at rest and with the Valsalva maneuver. The parameters were added progressively according to their simplicity of use and their predictive capacity for identifying UP. We used two binary logistic regression models to predict UP. Model 1 was based on the difference in the pubis−uterine fundus distance at rest and with the Valsalva maneuver and the age of the patient [AUC: 0.967 (95% CI, 0.939−0.995; p < 0.0005)]. Model 2 used the difference in the pubis−uterine fundus distance at rest and with the Valsalva maneuver, age, avulsion and ballooning (AUC: 0.971 (95% CI, 0.945−0.997; p < 0.0005)). In conclusion, the model based on the difference in the pubis−uterine fundus distance at rest and with the Valsalva maneuver and the age of the patient could predict 96.7% of patients with UP.


Assuntos
Prolapso de Órgão Pélvico , Prolapso Uterino , Feminino , Humanos , Ultrassonografia , Prolapso Uterino/diagnóstico por imagem , Útero/diagnóstico por imagem , Manobra de Valsalva
16.
Tomography ; 8(3): 1270-1276, 2022 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-35645391

RESUMO

The relationship between the anorectal angle (ARA) and the levator ani muscle (LAM) is well known. In this study, we aimed to demonstrate that the ARA changes when LAM avulsion occurs after vaginal delivery. This was a secondary, observational retrospective study with data obtained from three previous studies. Using transperineal ultrasound, the presence of avulsion was assessed when abnormal insertion of the LAM was observed in three central slices. In addition, the ARA was assessed in the midsagittal plane (at rest, in Valsalva and at maximum contraction) as the angle between the posterior border of the distal part of the rectum and the central axis of the anal canal. The ARA was higher in patients with bilateral LAM avulsion than in patients without LAM avulsion at rest (131.8 ± 14.1 vs. 136.2 ± 13.8), in Valsalva (129.4 ± 15.5 vs. 136.5 ± 14.4) and at maximum contraction (125.7 ± 15.5 vs. 132.3 ± 13.2). The differences between both groups expressed as the odds ratio (OR) adjusted for maternal age were 1.031 (95% confidence interval (CI), 1.001-1.061; p = 0.041) at rest, 1.036 (95% CI, 1.008-1.064; p = 0.012) in Valsalva and 1.031 (95% CI, 1.003-1.059; p = 0.027) at maximum contraction. In conclusion, LAM avulsion produces an increase in the ARA at rest, during contraction and in Valsalva, especially in cases of bilateral LAM avulsion.


Assuntos
Canal Anal , Diafragma da Pelve , Canal Anal/diagnóstico por imagem , Parto Obstétrico , Feminino , Humanos , Diafragma da Pelve/diagnóstico por imagem , Gravidez , Estudos Retrospectivos , Ultrassonografia
17.
Quant Imaging Med Surg ; 12(4): 2213-2223, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35371949

RESUMO

Background: We believe that physiotherapy with muscle training (MT) of the postpartum pelvic floor may lead to a change in the clinical management of patients with avulsion of the puborectal portion of the levator ani muscle (LAM). Our objective is to assess whether physiotherapy with MT of the postpartum pelvic floor in patients with LAM avulsion produces changes in pelvic floor morphology evaluated by 3/4D transperineal ultrasound. Methods: This parallel randomized controlled trial (RCT) included 97 primiparous patients. A study was conducted in three parts. In the first part (3 months postpartum), primiparous patients with LAM avulsion were recruited, and the levator hiatus and the LAM areas were measured using 3/4D transperineal ultrasound. In the second part (3 to 6 months postpartum), patients were randomized into two groups, with one undergoing rehabilitation (experimental group) and another without rehabilitation (control group). At the end of 6 months, a new transperineal ultrasound was performed. In the third part (9 months postpartum), the levator hiatus and LAM dimensions were analyzed again. The RCT was registered at ClinicalTrials.gov (NCT03686956). Project PI16/01387 funded by Instituto de Salud Carlos III (Spain) integrated in the national I+D+i 2013-2016 and cofounded by the European Union (ERDF/ESF, "Investing in your future"). Results: A total of 92 completed the study, including 46 patients in the experimental group and 46 in the control group. The experimental group had a greater LAM area at 6 months (9.2±1.9 vs. 7.6±2.1 cm2, P=0.008; 95% CI: 0.6-3.0) and 9 months after labor (9.4±2.7 vs. 7.6±2.0 cm2, P=0.012; 95% CI: 0.4-3.2), which was not observed at 3 months postpartum (8.3±1.6 vs. 7.5±2.3 cm2; P=0.183; 95% CI: 0.39-1.99). The levator hiatus area decreased more in the experimental group in almost all comparisons. The most significant change occurred from 3 to 6 months during the Valsalva maneuver (-3.92±5.12 vs. 0.45±3.06 cm2; P<0.005; 95% CI: 2.64-5.00). Conclusions: Women with a rehabilitated LAM through physiotherapy showed a significant reduction in the levator hiatus area during Valsalva while receiving in-person physical therapy (3 to 6 months after delivery). These differences did not persist once physical therapy was completed (6 to 9 months after delivery). Trial Registration: ClinicalTrials.gov identifier NCT03686956.

18.
Quant Imaging Med Surg ; 12(2): 959-966, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35111597

RESUMO

BACKGROUND: Recently, a specific methodology has been defined, using transperineal ultrasound, for the differential diagnosis of middle compartment prolapse [uterine prolapse (UP) or cervical elongation (CE) without UP] based on the difference in the pubis-uterine fundus distance at rest and with the Valsalva maneuver, with a cutoff point of 15 mm. The objective of this study was to validate the diagnostic utility of a ≥15 mm difference between the pubis-uterine fundus distance at rest and during the Valsalva maneuver to define UP in a multicenter study. METHODS: This prospective multicenter observational study included 94 patients (UP =51; CE without UP =43). The clinical examination was based on the International Continence Society Pelvic Organ Prolapse Quantification (ICS POP-Q) system for assessing pelvic organ prolapse (POP) and patients were candidates for corrective surgery of the middle compartment of the pelvic floor (correction of UP or CE without UP). The ultrasound study was performed by transperineal ultrasound (B-mode) with the patient undergoing dorsal lithotomy. The distance evaluation was performed in relation to the posteroinferior pubic margin in the midsagittal plane, with reference to the uterine fundus (established as the most distal hyperechogenic) line from the pubis to the uterine fundus at rest and with the Valsalva maneuver. We defined UP detected using UP as a difference of ≥15 mm between the pubis-uterine fundus distance at rest and with the Valsalva maneuver. Agreement between the clinical and ultrasound diagnosis of UP was assessed using the Cohen kappa coefficient of agreement and its 95% CIs. RESULTS: The ultrasound diagnosis of global UP at the three centers showed very good agreement, with a kappa index of 0.826 (0.71, 0.94). The agreement of ultrasound with the clinical diagnosis of UP using the ICS POP-Q system was very good for each of the hospitals [Hospital 1: 0.814 (0.64, 0.98), Hospital 2: 0.847 (0.64, 1) and Hospital 3: 0.824 (0.59, 1)]. CONCLUSIONS: A difference of ≥15 mm between the pubis-uterine fundus distance at rest and during the Valsalva maneuver for the diagnosis of UP presents very good agreement with the results of clinical evaluation with the ICS POP-Q system.

19.
Int Urogynecol J ; 33(10): 2825-2831, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-34618192

RESUMO

OBJECTIVES: Our study aims to determine the interobserver variability of different ultrasound measurements (pubis-cervix distance, pubis-uterine fundus distance, and pubis-Douglascul-de-sac distance) previously analyzed for the ultrasound differential diagnosis of uterine prolapse (UP) and cervical elongation CE without UP. MATERIALS AND METHODS: We conducted a prospective observational study with 40 patients scheduled to undergo surgical correction of UP and CE without UP. All patients underwent pelvic floor ultrasound examination by an examiner (E1) who acquired ultrasound images. Using these images, E1 measured the distances for the ultrasound differential diagnosis of UP and CE without UP, and these distances were compared with those measured by the other examiner (E2). Values were analyzed by calculating ICCs with 95% CIs. RESULTS: For UP, excellent reliability was obtained for all measurements except the pubis-Douglascul-de-sac measurement at rest, which was moderate (ICC 0.596; p = 0.028) and for the difference between the pubis-Douglascul-de-sac measurement at rest and during the Valsalva maneuver, which was good (ICC 0.691; p < 0.0005). For CE without UP, interobserver reliability was excellent for all measurements analyzed except the pubis-cervix measurement during the Valsalva maneuver, which was moderate (ICC 0.535; p = 0.052) and for the pubis-Douglascul-de-sac measurement at rest, which was good (ICC 0.768; p < 0.0005). CONCLUSIONS: There is excellent interobserver reliability in measurements of the difference in the distance from the pubic symphysis to the uterine fundus at rest and during the Valsalva maneuver for both UP and CE without UP, which are used for the ultrasound differential diagnosis of UP and CE without UP.


Assuntos
Prolapso de Órgão Pélvico , Prolapso Uterino , Diagnóstico Diferencial , Feminino , Humanos , Imageamento Tridimensional/métodos , Variações Dependentes do Observador , Prolapso de Órgão Pélvico/diagnóstico por imagem , Reprodutibilidade dos Testes , Ultrassonografia/métodos , Prolapso Uterino/diagnóstico por imagem , Manobra de Valsalva
20.
Viruses ; 13(11)2021 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-34835136

RESUMO

Pregnant women are particularly vulnerable to the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic. In addition to unfavorable perinatal outcomes, there has been an increase in obstetric interventions. With this study, we aimed to clarify the reasons, using Robson's classification model, and risk factors for cesarean section (C-section) in SARS-CoV-2-infected mothers and their perinatal results. This was a prospective observational study that was carried out in 79 hospitals (Spanish Obstetric Emergency Group) with a cohort of 1704 SARS-CoV-2 PCR-positive pregnant women that were registered consecutively between 26 February and 5 November 2020. The data from 1248 pregnant women who delivered vaginally (vaginal + operative vaginal) was compared with those from 456 (26.8%) who underwent a C-section. C-section patients were older with higher rates of comorbidities, in vitro fertilization and multiple pregnancies (p < 0.05) compared with women who delivered vaginally. Moreover, C-section risk was associated with the presence of pneumonia (p < 0.001) and 41.1% of C-sections in patients with pneumonia were preterm (Robson's 10th category). However, delivery care was similar between asymptomatic and mild-moderate symptomatic patients (p = 0.228) and their predisposing factors to C-section were the presence of uterine scarring (due to a previous C-section) and the induction of labor or programmed C-section for unspecified obstetric reasons. On the other hand, higher rates of hemorrhagic events, hypertensive disorders and thrombotic events were observed in the C-section group (p < 0.001 for all three outcomes), as well as for ICU admission. These findings suggest that this type of delivery was associated with the mother's clinical conditions that required a rapid and early termination of pregnancy.


Assuntos
COVID-19 , Cesárea , Complicações Infecciosas na Gravidez , Adulto , COVID-19/complicações , Comorbidade , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Pessoa de Meia-Idade , Gravidez , Resultado da Gravidez , Trimestres da Gravidez , Nascimento Prematuro , Estudos Prospectivos , Fatores de Risco , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...